A

Larger axon diameter lowers internal resistance and allows local currents to spread farther and faster, making conduction velocity roughly proportional to fiber diameter, while action-potential amplitude and refractory/latency periods are largely diameter-independent [Waxman, 1980, PMID 6245357; Tackmann et al., 1976, PMID 57218].